Flow Meter Expert | Industrial Flow Meter ManufacturerFlow Meter Expert | Industrial Flow Meter Manufacturer
  • Email

    arkellzheng@gmail.com
  • Whatsapp

    +8618852320787
  • WeChat

    +8618852320787
  • Home
  • Products
    • Electromagnetic Flow Meter
    • Orifice flowmeter
    • Precession Vortex flowmeter
    • Thermal Mass Flow Meter
    • Turbine flow meter
    • Ultrasonic flow meter
    • Vortex flowmeter
  • Industry Applications
    • Oil & Gas
    • Water industry
    • Heating/Cooling
    • Food & Beverage
    • Chemical industry
    • Metallurgy
    • Paper & Pulp
    • Pharmaceutical
    • Other
  • Services & Support
    • Support
    • Download
  • News
    • Company News

Hot news

  • Compressed Air Flow Metering: How to Find and Cost Your Leaks

    Compressed Air Flow Metering: How to Find and Cost Your Leaks

  • Steam Flow Measurement: Choosing Between Vortex, Orifice and Coriolis

    Steam Flow Measurement: Choosing Between Vortex, Orifice and Coriolis

  • Pharmaceutical Water Flow Measurement: WFI, Purified Water and CIP/SIP Loops

    Pharmaceutical Water Flow Measurement: WFI, Purified Water and CIP/SIP Loops

  • Flow Meters in Pulp and Paper Mills: Black Liquor, White Water and Stock Lines

    Flow Meters in Pulp and Paper Mills: Black Liquor, White Water and Stock Lines

Flow Meter Technology Comparison: 11 Types Compared

Eleven flow measurement technologies, compared across the twelve criteria that actually decide a specification. Use this when you need to narrow the field quickly, then confirm the detail on the individual product page.

Technology Best for Conductivity Viscosity limit Typical accuracy Turndown Straight run (up / down) Pressure loss Moving parts Main wear item Typical application Main limitation
Electromagnetic Conductive liquids, slurries Yes, 5 µS/cm min No practical limit ±0.5% of reading 20:1 5D / 3D None (full bore) None Liner + electrodes Billing, wastewater, slurry Will not measure non-conductive fluids
Clamp-on ultrasonic Clean single-phase liquids Not required Moderate ±1% of reading 40:1 10D / 5D None None Couplant, mounts Retrofit, large mains, surveys Needs full pipe and measurable wall
Vortex Steam, gas, low-viscosity liquids Not required Low only ±1.0% of reading 20:1 15–30D / 5D Low None None significant Steam, compressed air Signal dies below min Reynolds number
Liquid turbine Clean low-viscosity liquids Not required <10 cSt ±0.5% of reading 10:1 10D / 5D Very low Rotor + bearing Bearing Water, diesel, batching Bearing wear shifts K-factor
Gas turbine Natural gas, LPG, air Not required Low only ±1.0% of reading 10:1 10D / 5D Low Rotor + bearing Bearing Gas custody transfer Needs T/P compensation
Thermal mass Clean dry gas Not required Low ±1–2% of reading 100:1 15–20D / 5D Very low Heated sensor Sensor coating Compressed air, biogas Coating drifts reading silently
Roots / rotary Natural gas, town gas Not required Low ±0.5–1% of reading 100:1 Short Low, constant Rotors Rotors, seals Low-pressure gas distribution Not for dirty or wet gas
Orifice / DP Steam, gas, liquids Not required Any ±1–2% of reading 3–4:1 20–40D / 5D High, permanent None Plate erosion Steam, high temperature Permanent pressure loss; blocked impulse lines
Balanced orifice Steam, gas, liquids Not required Any ±0.5% of reading 5:1 5–10D / 5D Moderate None Plate erosion Retrofit steam metering Still a DP device with taps
Precession vortex Natural gas, LPG, coal gas Not required Low ±1.5% of reading 30:1 10D / 5D Low None None significant Gas with built-in compensation Not for steam or dirty gas
Coriolis Liquids, gases, slurries Not required Any ±0.1–0.2% of reading 100:1 None Low to moderate Vibrating tubes Tube fatigue Custody transfer, dosing Cost; limited to smaller sizes

How to read this table

Start with the conductivity column. If the fluid does not conduct, three of these technologies disappear immediately and the shortlist writes itself.

Then look at viscosity. Above about 10 cSt the turbine options fall away, and above 20 cSt most of the velocity-based technologies do too.

Then look at straight run. On a retrofit or a skid with fixed dimensions, the piping constraint usually eliminates more options than the accuracy requirement does.

Accuracy comes last, because it is the specification people argue about most and the one that matters least once the installation is wrong. A plus or minus 0.5 percent meter installed after a close-coupled elbow will not hold half a percent.

Two things this table cannot tell you

Cost. The spread between the cheapest and most expensive option for the same line size is roughly ten to one, and it depends on materials, pressure rating and connection standard as much as on technology. Ask for a quotation on the specific duty.

Whether your installation will let the meter perform. Every accuracy figure above assumes the straight run, the full pipe and the grounding are all correct. Those are installation conditions, not product features.

Checking a specific duty

If you have the flow, the bore and the fluid, the flow rate and pipe velocity calculator will tell you whether the resulting velocity sits in a sensible band before you go any further.

For the decision process in order, see how to choose a flow meter. For the accuracy figures themselves and what they mean at low flow, see flow meter accuracy explained.

Product pages by technology

  • Electromagnetic flow meter
  • Clamp on ultrasonic flow meter
  • Vortex flow meter
  • Liquid turbine flow meter
  • Gas turbine flow meter
  • Thermal gas mass flow meter
  • Gas Roots flow meter
  • Balanced orifice flow meter
  • Precession vortex flow meter
  • 80G radar level gauge

© 2026. All Rights Reserved.

Back to Top

  • Home
  • Products
  • WhatsApp
  • Email