Flow Meter Expert | Industrial Flow Meter ManufacturerFlow Meter Expert | Industrial Flow Meter Manufacturer
  • Email

    arkellzheng@gmail.com
  • Whatsapp

    +8618852320787
  • WeChat

    +8618852320787
  • Home
  • Products
    • Electromagnetic Flow Meter
    • Orifice flowmeter
    • Precession Vortex flowmeter
    • Thermal Mass Flow Meter
    • Turbine flow meter
    • Ultrasonic flow meter
    • Vortex flowmeter
  • Industry Applications
    • Oil & Gas
    • Water industry
    • Heating/Cooling
    • Food & Beverage
    • Chemical industry
    • Metallurgy
    • Paper & Pulp
    • Pharmaceutical
    • Other
  • Services & Support
    • Support
    • Download
  • News
    • Company News

Product Menu

  • Company News

Featured Articles

  • Steam Flow Measurement: Choosing Between Vortex, Orifice and Coriolis

    Steam Flow Measurement: Choosing Between Vortex, Orifice and Coriolis

  • Pharmaceutical Water Flow Measurement: WFI, Purified Water and CIP/SIP Loops

    Pharmaceutical Water Flow Measurement: WFI, Purified Water and CIP/SIP Loops

  • Flow Meters in Pulp and Paper Mills: Black Liquor, White Water and Stock Lines

    Flow Meters in Pulp and Paper Mills: Black Liquor, White Water and Stock Lines

  • Flow Measurement in Steel Plants: Blast Furnace Gas, Coke Oven Gas and Cooling Water

    Flow Measurement in Steel Plants: Blast Furnace Gas, Coke Oven Gas and Cooling Water

Hot Tags.

  • Electromagnetic flowmeter
  • Application Cases
  • Balanced orifice flow meter
  • Electromagnetic Flowmeter Flange Type
  • Flange Type Liquid Turbine Flow Meter
  • Flange Type Thermal Gas Mass Flow Meter
  • Gas Roots Flow Meter
  • Gas Turbine Flow Meter
  • Gas vortex precessionflowmeter
  • Mass flow meter
  • New Products
  • Standard type vortex flow meter
  • Water conservancy and irrigation
  • water conservancy irrigation
  • Water treatment

Compressed Air Flow Metering: How to Find and Cost Your Leaks

Technical Guides

Compressed air is the most expensive utility in most plants per unit of energy delivered, and typically 20 to 30 percent of it escapes through leaks. The measurement that pays for itself fastest is not the one on the compressor outlet. It is the one that lets you prove where the air is going.

Why thermal mass is the usual choice

Compressed air is measured by mass or by standard volume, not by actual volume, because the same mass occupies a different volume at different pressures. A thermal mass meter reads mass flow directly, so it needs no separate pressure and temperature compensation.

That simplicity is the whole argument. One instrument instead of three, and the reading is already in the units an energy audit needs.

The alternatives all have a catch. A vortex meter works but needs 15 to 20 diameters of straight run that compressed air headers rarely have. An orifice plate costs permanent pressure loss, which on a compressed air system you pay for twice: once at the compressor and again at the dryer. An ultrasonic clamp-on unit works but struggles with the low density and thin pipe walls typical of air headers.

Where to put the meters

Four locations, in order of what they tell you.

  1. After the dryer, on the main header. This is the true consumption figure, after the dryer losses and before distribution. It is the number to compare against compressor output.
  2. Per department or per building. This is where leak hunting starts, because it turns an abstract percentage into an allocation argument.
  3. On the large individual users. Any machine that consumes more than about 10 percent of total capacity is worth its own meter.
  4. After the compressor, before the dryer. Only if you want to quantify dryer purge loss, which can be surprisingly large on heatless desiccant dryers.

The leak test that actually works

You do not need a ultrasonic leak detector to find the big ones. You need a quiet period and a baseline.

Shut down production, leave the compressors running, and watch the header meter. Whatever flow remains is leakage. On a plant with 500 kW of compressor capacity, a 25 percent leak rate means 125 kW running continuously for nothing. At 0.10 per kWh that is roughly 100,000 per year, which is usually more than the metering project costs.

Then isolate by department, one valve at a time. The meter that shows a drop is pointing at the department with the problem.

Sizing the meter

Two things matter more than the datasheet accuracy.

Turndown. Compressed air systems swing enormously between shifts. A meter with 100:1 turndown holds accuracy through that swing; a meter with 10:1 does not. This is where thermal mass earns its place.

Insertion or inline. Below DN80, use an inline body. Above DN100, an insertion probe costs a fraction of a full-bore meter and installs through a tapping rather than a cut.

What the number is good for

Once you have per-department figures, three things become possible that were not before.

You can charge compressed air back to departments, which changes behaviour faster than any memo. You can size a new compressor on measured demand rather than on the sum of nameplate ratings. And you can prove the saving after a leak repair programme, which is what justifies the next round of funding.

A note on units

Compressed air is normally reported in Nm3/h or SCFM, meaning standard conditions. Make sure the meter is configured for the standard conditions your plant uses, because a reference temperature of 0 degrees Celsius against 20 degrees Celsius is a 7 percent difference before you have measured anything.

To check line velocities on the distribution pipework, the flow rate and pipe velocity calculator handles the conversion.

Related reading

The thermal gas mass flow meter range covers DN25 to DN300 for compressed air and process gas. For the technology comparison behind the choice, see how to choose a flow meter.

Steam Flow Measurement: Choosing Between Vortex, Orifice and Coriolis
« Previous post 2026年10月25日 am4:19

Related Posts

  • Steam Flow Measurement: Choosing Between Vortex, Orifice and Coriolis
  • How to Size a Flow Meter: Five Numbers You Need Before You Ask for a Quote
  • Flow Meter Accuracy: What ±0.5% Actually Means in Practice
  • Flow Meter Reading Wrong? Eight Causes and How to Check Them
  • How to Choose a Flow Meter: A Practical Selection Guide
  • Flow Meter P&ID Symbols: How to Read Them on a Drawing
  • Electromagnetic vs Ultrasonic Flow Meter: Which Should You Choose?
  • How Does a Turbine Flow Meter Work? Principle, K-Factor and Diagram
  • Vortex Flow Meter Straight Run Requirement (With Chart)

© 2026. All Rights Reserved.

Back to Top

  • Home
  • Products
  • WhatsApp
  • Email